Wire saw machine automatic cutting wireless remote control DH12S-P6S

Hasiera|urrutiko kontrola industriala|Wire saw machine automatic cutting wireless remote control DH12S-P6S

Wire saw machine automatic cutting wireless remote control DH12S-P6S

Aplikazio:Specially used for crawler wire saw machine

1.Supports automatic cutting function, automatically adjusts cutting speed according to motor current feedback

2.Oztoporik gabeko transmisio distantzia da 200 metroak.

3. Support DC driver.

4. Supports multiple cutting parameter settings, such as cutting current, cutting speed limit, etab.

5. Supports switching between wire saw and blade saw modes. Different cutting parameters can be set in different modes.


  • Energia kontsumo txikiko diseinua
  • Erabilera erraza

Deskribapena

1.Produktu eredua

 

Eredua: DH12S-P6S

Ekipamendu aplikagarriak:wire saw/blade saw machine

2.Produktu osagarrien diagrama

Ohar: Hiru antenetako bat aukeratu dezakezu. Bentosaren antena estandarra da lehenespenez.

3.Urruneko agintearen etengailuaren deskribapena

4.Displaycontent introduction

Main motor speed: Main: 0-50
Traveling motor speed: Line: 0-50
Maximum speed limit of automatic cutting traveling motor: Speed: 0-30
(parameters adjustable)
Automatic cutting main motor setting current: Setting: 28 (parameters adjustable)
Swing arm motor speed: Swing: 0-50

Tentsio baxua: Urruneko agintearen bateria baxuegia da, mesedez ordezkatu bateria.

Sarea erori egin da: Hari gabeko seinalea eten da. Mesedez, egiaztatu hargailuaren potentzia, piztu ezazu berriro, eta berrabiarazi urrutiko agintea.

5.Urruneko kontrol funtzioaren funtzionamendu-argibideak

1)Turn on the remote control

Hargailua piztuta dagoenean, the D2 power light on the receiver is always on, andthe D1 signal light starts to flash; instalatu bi AA bateria urrutiko agintean, piztu etengailua, and the display will show the motor speed, abiarazte arrakastatsua adierazten du.

2)Large motor and speed regulation/Main motor and speed regulation

Press and holdSpeed Regulation Enable”, turn theForward/Reverseswitch to forward, and the receiver’s main motor will turn on;
Press and holdSpeed Regulation Enable”, turn theForward/Reverseswitch to reverse, and the receiver’s main motor will reverse and turn on;Simply move the switch to the middle or reverse direction, and the main motor will stop immediately without pressing the speed control enable button;Rotate thebig motorknob to adjust the speed regulation voltage of the receiver’s main motor inverter to 0-10V;

3)Traveling motor

Press and holdSpeed Adjustment Enable”, turn theForward/Reverseswitch to forward or backward, and the walking motor will move at a high speed of 50;

4)Swing arm motor and speed regulation

Turn theSwing Arm/Reverseswitch to swing arm or retreat, and the receiver’s swing arm motor starts; then rotate theSpeed Adjustmentknob to adjust the swing arm motor speed;

Press and holdSpeed Adjustment Enable”, and then pull theSwing Arm/Reverseswitch, the swing arm motor will move at a high speed of 50;

5)Travel motor speed limit adjustment

Press and hold thespeed adjustment enablebutton and rotate thespeed adjustmentto adjust the maximum speed limit of the traveling motor during automatic cutting;

6) Automatic cutting

The first step is to start the main motor; the second step is to adjust the maximum speed limit of the walking motor; the third step is to move theforward/reverseswitch forward or backward to enter the automatic cutting mode;

7) Parameter menu (users are prohibited from modifying it without permission)

Enter the parameter menu:In manual mode, when the main motor speed is 0, push the forward/reverse switch up three times in a row, and then push it down three times in a row to enterthe parameter menu;
Irten parametroen menutik: Turn the speed adjustment knob, select save or not save, and press the enable button to confirm;
Rated current: The maximum value of the main motor current, unit Ampere;
Speed adjustment parameters: Automatic cutting control parameters, default 800, unit milli second,modification is prohibited;
Deceleration parameter: When the cutting current change value exceeds this value, rapid deceleration begins, unit Ampere;
Acceleration a1: When the cutting current is lower than the set cutting current, the speed value increased by each acceleration of the walking motor;
Deceleration a2: When the cutting current is higher than the set cutting current, the speed value reduced by each deceleration of the walking motor;
Swing arm current: Default value, modification is prohibited;
Stop time: After the automatic mode current overload shutdown, the current will be detected again after a period of time. If it is less than the set current, the walking motor will automatically start; unit second, default value, modification is prohibited;
Maximum current: The range of main motor feedback current, unit Ampere;
Maximum host: Remote control main motor speed adjustment display range;
Maximum walking: Invalid parameter;
Speed limit offset: During automatic cutting, the remote control display walking motor speed limit = 50% of this parameter;
Increase sensitivity: When the main motor feedback current increases, each time the increase exceeds this value, the walking motor accelerates;
Decrease sensitivity: When the feedback current of the main motor decreases, and each time the decreasing value exceeds this value, the walking motor decelerates;
Sensitivity offset: Add and subtract the offset increment of the sensitivity parameter;
Set current: Automatic cutting, the threshold of main motor feedback current. If this value is exceeded,the walking motor starts to decelerate;Below this value, the walking motor starts to accelerate;unit: Ampere;
Idling exit: When the automatic mode starts, if the main motor feedback current is less than this value,it will be in the idling mode.If it is greaterthan this value, it will exit the idling mode and enter the cutting mode.Unit is ampere;
No-load current:When automatic mode starts, if the main motor feedback current is less than this value,it is in no-load mode.If it is greaterthan this value, it will exit the no-load mode and enter the cutting mode.Unit is Ampere;
Swing arm speed: Initial speed of swing arm motor when starting up;
Cutting mode: Switch between blade saw and wire saw modes, and the parameters will switch accordingly after the switch; in blade saw mode, the remote control display adds a swing arm motor, while in wire saw mode, there is no swing arm motor;
Debounce time: When the main motor feedback current exceeds the stop current, the feedback current will be continuously detected. The debounce time is the duration of this continuous detection.After this time, if the main motor current still exceeds the stop current, the walking motor will stop;otherwise, the walking motor will stop. The motor will keep going;
Stop current: The main motor feedback current exceeds this value, and the walking motor will stop;Unit is Ampere;
Offset default: The initial value of the walking motor speed limit when the remote control is turned on = 50% of this value;

6.Urruneko kontrolaren ezaugarri elektrikoak

7.Urruneko kontrolaren tamaina

Produktu honen azken interpretazio eskubidea gure enpresari bakarrik dagokio.

Zehaztapen-parametroa

Iritziak

Oraindik ez dago iritzirik.

Izan zaitez berrikusten lehena "Wire saw machine automatic cutting wireless remote control DH12S-P6S

Zure helbide elektronikoa ez da argitaratuko. Beharrezko eremuak markatuta daude *

Wixhc Teknologia

CNC industrian liderra gara, haririk gabeko transmisioan eta CNC Motion Control-ean espezializatuta dago 20 urte. Dozenaka patentatutako teknologia ditugu, eta gure produktuak oso ondo saltzen dira 40 mundu osoko herrialdeak, ia aplikazio tipikoak metatzen 10000 bezeroei.

Azken txioak

Buletina

Eman izena azken berriak eta eguneratzeko informazioa lortzeko. Ez kezkatu, ez dugu spamik bidaliko!