<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Uncategorized &#8211; Wixhc Technology</title>
	<atom:link href="https://www.wixhc.cn/mw/product-category/uncategorized/feed" rel="self" type="application/rss+xml" />
	<link>https://www.wixhc.cn</link>
	<description>Industry Leader</description>
	<lastBuildDate>Wed, 05 Nov 2025 06:21:59 +0000</lastBuildDate>
	<language>mw</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.5</generator>
	<item>
		<title>Wired electronic handwheel Instruction Manual</title>
		<link>https://www.wixhc.cn/product/wired-electronic-handwheel-instruction-manual</link>
		
		<dc:creator><![CDATA[xia xiaoqin]]></dc:creator>
		<pubDate>Wed, 05 Nov 2025 06:13:13 +0000</pubDate>
				<guid isPermaLink="false">https://www.wixhc.cn/?post_type=product&#038;p=4678</guid>

					<description><![CDATA[1. Use a 6-core aviation plug cable for connection, with a handwheel cable length of 10 meters. 2. The handwheel screen can display system workpiece coordinates, mechanical coordinates,feed rate, axis selection, magnification, and other information. 3. Support emergency stop button, switch IO signal output, and the hand wheel shutdown emergency stop is still valid. 4.]]></description>
										<content:encoded><![CDATA[<p><img fetchpriority="high" decoding="async" src="https://www.wixhc.com/uploads/251105/5-251105113310637.jpg" alt="" width="700" height="497" data-cke-saved-src="/uploads/251105/5-251105113310637.jpg" /></p>
<p><strong>1. Khoom taw qhia</strong></p>
<div>Lub tshuab hluav taws xob yog siv rau kev qhia phau ntawv, Positioning, cov cuab yeej sib txig, thiab lwm yam kev ua haujlwm ntawm CNC tshuab cuab yeej. Cov qauv ntawm lub log tes hluav taws xob no yog qhov tseeb Siemens zaub xaim handwheel. Lub log tes txuas nrog X130 interface ntawm Siemens system los ntawm lub network cable, thiab cov kaw lus sib koom tes tau nyeem thiab tso tawm ntawm lub log LCD npo los ntawm S7 raws tu qauv kev sib txuas lus. Lub log tes tseem tuaj yeem tswj hwm qhov system axis xaiv, magnification, nyees khawm, andother signals through communication.</div>
<div>
<div><strong>2.Cov khoom lag luam ua haujlwm</strong></div>
<div>
<div>1. Use a 6-core aviation plug cable for connection, with a handwheel cable length of 10 meters.</div>
<div>2. Lub handwheel screen yuav tso saib system workpiece coordinates, mechanical coordinates,pub tus nqi, axis xaiv, magnification, and other information.</div>
<div>3. Txhawb nqa thaum muaj xwm ceev nres khawm, Hloov IO teeb liab tso zis, and the hand wheel shutdown emergency stop is still valid.</div>
<div>4. Supports 6 Kev cai nyees khawm, hloov IO teeb liab, and can output signals to the system through IO wiring or communication.</div>
<div>5. Supports 6 or 8 axis control, with switch IO signals that can be output to the system through IO wiring or communication.</div>
<div>6. Supports 3 or 4 theem ntawm kev tswj hwm lub zog, with switch IO signals that can be output to the system through IO wiring or communication.</div>
<div>7. Txhawb nqa mem tes encoder, 100 pulses ib tig, can output signals to the system through AB pulse wiring.</div>
<div>8. Txhawb Siemens S7 raws tu qauv thiab Siemens 828D, 840DSL, ONE and other model systems.</div>
</div>
</div>
<p>&nbsp;</p>
<div><strong>3. Cov khoom lag luam specifications</strong></div>
<div>
<table border="1" cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td>Handwheel khiav hauj lwm fais fab mov voltage</td>
<td>DC24V / 1A</td>
</tr>
<tr>
<td>Receiver fais fab mov voltage</td>
<td>DC24V / 1A</td>
</tr>
<tr>
<td>Receiver IO tso zis load ntau</td>
<td>DC24V</td>
</tr>
<tr>
<td>Handwheel kawg cable ntev</td>
<td>10m</td>
</tr>
<tr>
<td>Receiver kawg cable ntev</td>
<td>1m</td>
</tr>
<tr>
<td>Receiver kawg network cable ntev</td>
<td>3m</td>
</tr>
<tr>
<td>Kev khiav hauj lwm kub</td>
<td>-25°C&lt;X&lt;55°C</td>
</tr>
<tr>
<td>Anti-caij nplooj zeeg qhov siab</td>
<td>1m</td>
</tr>
<tr>
<td>Kev cai khawm kom muaj nuj nqis</td>
<td>6</td>
</tr>
<tr>
<td>Khoom qhov ntev</td>
<td>233*90.7*77.4(hli)</td>
</tr>
</tbody>
</table>
<div>
<p><strong>4.Khoom muaj nuj nqi taw qhia</strong></p>
</div>
<div>
<p><img decoding="async" src="https://www.wixhc.com/uploads/251105/5-251105113931114.jpg" alt="" width="700" height="1155" data-cke-saved-src="/uploads/251105/5-251105113931114.jpg" /></p>
<div>Ceeb toom:</div>
<div>Thaum muaj xwm ceev nres khawm:</div>
<div>Nias lub pob nres thaum muaj xwm ceev, thiab ob pawg ntawm kev kub ntxhov nres IO tso zis ntawm lub receiver yuav raug txiav tawm, and all functions of the handwheel will be invalid.</div>
<div>Tom qab tso tawm qhov chaw nres tsheb thaum muaj xwm ceev, the emergency stop IO output on the receiver is closed, and all functions of the handwheel are restored.</div>
<div>(2) Screen zaub:</div>
<div><img decoding="async" src="https://www.wixhc.com/uploads/251105/5-251105114042945.jpg" alt="" width="700" height="183" data-cke-saved-src="/uploads/251105/5-251105114042945.jpg" /></div>
</div>
</div>
<p>&nbsp;</p>
<div>PLC: 0000 qhia tias lub network cable tsis txuas nrog, PLC: 1010 indicates that the network cable is successfully connected to the PLC system.</div>
<div>PLC: 1110 sawv cev rau kev sau ntawv zoo ntawm cov ntaub ntawv system rau lub log tes, PLC: 0001 represents successful connection to the computer.</div>
<div></div>
<div>(3) Kev cai khawm:</div>
<div>6 Kev cai nyees khawm, txhua tus sib raug rau ib qho IO tso zis taw tes ntawm lub txais, also connected to the system through communication.</div>
<div>(4) Axis xaiv hloov:</div>
<div> The axis selection switch can switch the movement axis controlled by the handwheel.</div>
<div></div>
<div>(5) Qhib khawm:</div>
<div> Nias thiab tuav tog twg los ua kom lub pob ntawm ob sab los qhib lub mem tes encoder. T, release the enable button to enable IO output to disconnect.</div>
<div>i:a</div>
<div>controlled by the handwheel.</div>
<div>⑦ Pulse encoder:</div>
<div> o, b, emit a pulse signal, and control the movement of the machine axis.</div>
<div>a:</div>
<div>
<p> w, g, used for handwheel power supply and communication.</p>
<p><strong>5. Product accessory diagram </strong><br />
<img decoding="async" src="https://www.wixhc.com/uploads/251105/5-2511051142353S.jpg" alt="" width="700" height="1030" data-cke-saved-src="/uploads/251105/5-2511051142353S.jpg" /></p>
<div><strong>6. Product Installation Guide<br />
6.1 n</strong></div>
<div>
<div>1. Install the receiver into the electrical cabinet through the screw holes at the four corners.</div>
<div>2. a. Connect the device to the receiver through cables and connect the receiver to the X130 interface of the system using Ethernet cables.</div>
<div>3. After fixing the receiver, install the aviation plug base at the handwheel opening position on the panel, and plug the other end of the base into the handwheel interface on the receiver. Then insert the aviation plug of the handwheel cable into the base and tighten the fixing device.</div>
<div></div>
</div>
</div>
<p>&nbsp;</p>
<div>
<p><strong>6.2 Receiver installation dimensions</strong></p>
<p><img decoding="async" src="https://www.wixhc.com/uploads/251105/5-251105114415144.jpg" alt="" width="700" height="366" data-cke-saved-src="/uploads/251105/5-251105114415144.jpg" /></p>
<p><strong>6.3 Installation dimensions of aviation plugs</strong><br />
<img decoding="async" src="https://www.wixhc.com/uploads/251105/5-251105114451256.jpg" alt="" width="700" height="227" data-cke-saved-src="/uploads/251105/5-251105114451256.jpg" /></p>
<div><strong>6.4 Receiver Wiring Reference Diagram</strong><br />
<img decoding="async" src="https://www.wixhc.com/uploads/251105/5-251105114543E6.jpg" alt="" width="700" height="957" data-cke-saved-src="/uploads/251105/5-251105114543E6.jpg" /><strong>7.Product Operation Instructions</strong></p>
</div>
<div>1. When the receiver is powered on and the working indicator light of the receiver flashes, connect the receiver to the computer with a network cable, set the fixed IP address of the computer, and use the network configuration tool software to set the network parameters of the handwheel function. For specific setting methods, refer to the &#8220;LXWGP-ETS Wired Handwheel User Manual&#8221;.</div>
<div>
<p> 2.After the receiver is set up, the system needs to program a PLC program. Please refer to the &#8220;LXWGP-ETS Different Siemens Numerical Control System Setting Methods&#8221; and PLC  program routine materials for details.</p>
<div>
<p>3.After completing the above settings, take the receiver to the machine electrical cabinet and install it. Pull out the network cable from the computer and plug it into the X130  interface of the system.Connect the receiver power supply and pulse line.3.</p>
<div>4.After completing the above settings, take the receiver to the machine electrical cabinet and install it. Pull out the network cable from the computer and plug it into the X interface of the system. Connect the receiver power supply and pulse line.</div>
<div>5. Select axis selection: Switch the axis selection switch and select the axis you want to operate on.</div>
<div>6. Select magnification: Switch the magnification switch and select the magnification level you need.</div>
<div>7. Moving axis: o, select the axis selection switch, select the magnification switch, and then rotate the pulse encoder to rotate the positive moving axis clockwise and the negative moving axis counterclockwise.</div>
<div>8. Press and hold any custom button to turn on the IO output of the corresponding button in the receiver, and release the button to turn off the output.</div>
<div>9. Nias lub pob nres thaum muaj xwm ceev, the corresponding emergency stop IO output of the receiver will be disconnected, the handwheel function will be disabled, release the emergency stop button, the emergency stop IO output will be closed, and the handwheel function will be restored.</div>
<div><strong>8.Cov Khoom Qauv Piav Qhia</strong></div>
</div>
</div>
</div>
<p><img decoding="async" src="https://www.wixhc.com/uploads/251105/5-251105135H94c.jpg" alt="" width="750" height="85" data-cke-saved-src="/uploads/251105/5-251105135H94c.jpg" /></p>
<div>① LXWGP represents a wired appearance style, and the receiver communication interface</div>
<div>is an Ethernet interface.</div>
<div>(2) : Represents Siemens system specific.</div>
<div>(3) : Sawv cev rau tus naj npawb ntawm axis xaiv hloov,  represents  axes, and  represents</div>
<div> axes.</div>
<div>④ : represents the type of axis selection and magnification signal, A represents</div>
<div>point-to-point output signal, and B represents encoded output signal.</div>
<div></div>
<p><img decoding="async" src="https://www.wixhc.com/uploads/251105/5-251105114QAa.jpg" alt="" width="700" height="162" data-cke-saved-src="/uploads/251105/5-251105114QAa.jpg" /></p>
<p><strong>9.Product trouble shooting</strong></p>
<p><img decoding="async" src="https://www.wixhc.com/uploads/251105/5-251105114923S5.jpg" alt="" width="700" height="713" data-cke-saved-src="/uploads/251105/5-251105114923S5.jpg" /></p>
<div><strong>10.Kev saib xyuas</strong></div>
<div>
<div>1. Please use it in a dry environment at room temperature and pressure to extend its service life.</div>
<div>2. Please avoid using in abnormal environments such as rain and water bubbles to extend the service life.</div>
<div>3. Please keep the appearance of the handwheel clean to extend its service life.</div>
<div>4. Please avoid squeezing, falling, bumping, etc. to prevent damage to the precision components inside the handwheel or accuracy errors.</div>
<div>5. Yog tias cov chaw taws teeb tsis siv ntev, please store the handwheel in a clean and safe place.During storage and transportation, attention should be paid to moisture and shock resistance.</div>
<div><strong>11. Safety Information</strong></p>
<div>1. Please read the instructions carefully before use and prohibit non professionals from operating.</div>
<div>2. If any abnormal situation occurs with the handwheel, please stop using it immediately and troubleshoot. Before troubleshooting, it is forbidden to use the faulty handwheel again to avoid safety accidents caused by unknown handwheel faults;</div>
<div>3. If repair is required, please contact the manufacturer. If the damage is caused by self repair, the manufacturer will not provide warranty</div>
</div>
</div>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>