1. Chigadzirwa Chekutanga
Electronic handwheel is used for manual guidance, chinzvimbo, tool alignment, and other operations on CNC machine tools. This model of electronic handwheel is a Siemens actual display wired electronic handwheel. The handwheel is connected to the X130 interface of the Siemens system through a network cable, and the system coordinates are read and displayed on the LCD screen of the handwheel through S7 protocol communication. The handwheel can also control system axis selection, Magnificial, buttons, andother signals through communication.
2.Chigadzirwa chinoshanda maitiro
1. Shandisa 6-core aviation plug tambo yekubatanidza, neiyo ruoko rwebhuruu 10 metres.
2. Iyo ruoko rwakagadziriswa runokwanisa kuratidza system workmieceres, Mechancal inoronga,dhaireke, Axis kusarudzwa, Magnificial, uye rumwe ruzivo.
3. Tsigira Emergency Stop bhatani, switch io signal kubuda, uye ruoko rwevhiri remaoko shutdown emergency yekumira ichiri kushanda.
4. Zvinotsigira 6 Tsika mabhatani, switch io signals, uye inogona kubuda chiratidzo kuhurongwa kuburikidza neIO wiring kana kutaurirana.
5. Zvinotsigira 6 kana 8 axis kutonga, Nekuchinjisa io signals inogona kuve yekubuda kune iyo system kuburikidza neIo wiring kana kutaurirana.
6. Zvinotsigira 3 kana 4 levels of magnification control, Nekuchinjisa io signals inogona kuve yekubuda kune iyo system kuburikidza neIo wiring kana kutaurirana.
7. Support pulse encoder, 100 pulses/turn, can output signals to the system through AB pulse wiring.
8. Supports Siemens S7 protocol and Siemens 828D, 840DSL, ONE and other model systems.
3. Zvigadzirwa Zvinyorwa
| Handwheel working power supply voltage |
DC24V/1A |
| Receivery Simba Kuwanikwa Voltage |
DC24V/1A |
| Receiver IO output load range |
DC24V |
| Hand wheel end cable length |
10m |
| Receiver end cable length |
1m |
| Receiver end network cable length |
3m |
| Operating temperature |
-25℃<X<55℃ |
| Anti-fall height |
1m |
| Custom Button Quantity |
6 |
| Product dimensions |
233*90.7*77.4(mm) |

ONA:
Emergency stop button:
Dzvanya bhatani reMergency Stop, uye maviri maviri emergency ekumisa io anobuda pane anogamuchira achabviswa, uye mabasa ese eiyo ruoko.
After releasing the emergency stop, the emergency stop IO output on the receiver is closed, and all functions of the handwheel are restored.
② Screen display:
PLC: 0000 indicates that the network cable is not connected, PLC: 1010 indicates that the network cable is successfully connected to the PLC system.
PLC: 1110 represents successful writing of system data to the handwheel, PLC: 0001 represents successful connection to the computer.
③ Custom button:
6 Tsika mabhatani, Imwe neimwe inoenderana neiyo inobuda pachena pane anogamuchira, also connected to the system through communication.
④ Axis selection switch:
The axis selection switch can switch the movement axis controlled by the handwheel.
⑤ Enable button:
Press and hold either enable button on both sides to activate the pulse encoder by shaking it. And the two groups on the receiver enable IO output to conduct, release the enable button to enable IO output to disconnect.
⑥ Magnification switch:The magnification switch can switch the magnification
controlled by the handwheel.
⑦ Pulse encoder:
Dzvanya uye Bata Bhatani bhatani, zunza pulse encoder, Bvisa chiratidzo chechiratidzo, and control the movement of the machine axis.
⑧ Handwheel cable:
Cable connecting the handwheel and receiver, aviation plug, used for handwheel power supply and communication.
5. Chigadzirwa Accessory Diagram

6. Chigadzirwa Kuisa Nhungamiro
6.1 Chigadzirwa kuisirwa matanho
1. Install the receiver into the electrical cabinet through the screw holes at the four corners.
2. Tarisa kune yedu yekugamuchira wiring diagram uye inoienzanisa neyako pane-saiti zvishandiso. Connect the device to the receiver through cables and connect the receiver to the X130 interface of the system using Ethernet cables.
3. After fixing the receiver, install the aviation plug base at the handwheel opening position on the panel, and plug the other end of the base into the handwheel interface on the receiver. Then insert the aviation plug of the handwheel cable into the base and tighten the fixing device.
6.2 Receiver kuisirwa zviyero

6.3 Installation dimensions of aviation plugs

6.4 Receiver Wiring Reference Diagram
7.Chigadzirwa Chigadzirwa Mirayiridzo
1. When the receiver is powered on and the working indicator light of the receiver flashes, connect the receiver to the computer with a network cable, set the fixed IP address of the computer, and use the network configuration tool software to set the network parameters of the handwheel function. For specific setting methods, refer to the “LXWGP-ETS Wired Handwheel User Manual”.
2.After the receiver is set up, the system needs to program a PLC program. Please refer to the “LXWGP-ETS Different Siemens Numerical Control System Setting Methods” and PLC program routine materials for details.
3.After completing the above settings, take the receiver to the machine electrical cabinet and install it. Pull out the network cable from the computer and plug it into the X130 interface of the system.Connect the receiver power supply and pulse line.3.
4.After completing the above settings, take the receiver to the machine electrical cabinet and install it. Pull out the network cable from the computer and plug it into the X interface of the system. Connect the receiver power supply and pulse line.
5. Select axis selection: Switch the axis selection switch and select the axis you want to operate on.
6. Sarudza Kukura: Switch the magnification switch and select the magnification level you need.
7. Kufambisa axis: Dzvanya uye Bata Bhatani bhatani, Sarudza iyo axis sarudzo switch, Sarudza switch, and then rotate the pulse encoder to rotate the positive moving axis clockwise and the negative moving axis counterclockwise.
8. Press and hold any custom button to turn on the IO output of the corresponding button in the receiver, and release the button to turn off the output.
9. Dzvanya bhatani reMergency Stop, Iyo inoenderana emergency yekumira io kubuda kweanogamuchira kuchabviswa, Iyo handwheel basa icharemara, Sunungura iyo Emergency Stop bhatani, Iyo emergency yekumira io kubuda ichavharwa, uye basa reruoko richadzoreredzwa.
8.Chigadzirwa Model Tsananguro

① LXWGP represents a wired appearance style, and the receiver communication interface
is an Ethernet interface.
② : Represents Siemens system specific.
③ : represents the number of axis selection switches, represents axes, and represents
axes.
④ : represents the type of axis selection and magnification signal, A represents
point-to-point output signal, uye b inomiririra yakapinda chiratidzo chekubuda chiratidzo.

9.Product trouble shooting

10.Maintenance
1. Ndokumbirawo uishandise munzvimbo yakaoma pamhepo tembiricha uye kumanikidzwa kuti uwedzere hupenyu hwebasa.
2. Ndokumbirawo udzivise kushandisa munzvimbo dzisina kujairika dzakadai semvura uye nemabhuru emvura kuti uwedzere hupenyu hwebasa.
3. Ndapota chengetedza kutaridzika kweiyo ruoko rwakaipa kuti uwedzere hupenyu hwayo hwebasa.
4. Ndokumbirawo kuti udzivise kunyura, kudonha, kuputika, etc. Kuti udzivise kukuvadzwa pazvinhu zvakanyatsojeka mukati meiyo ruoko kumusoro kana kururamisa zvikanganiso.
5. Kana isina kushandiswa kwenguva yakareba, please store the handwheel in a clean and safe place.During storage and transportation, kutariswa kunofanirwa kubhadharwa kune unyoro uye kushamisika kuramba.
11. Ruzivo rwekuchengetedza
1. Ndokumbirawo kuti muverenge iyo mirairo nokungwarira usati washandisa uye kurambidza vasingatomborambidza nyanzvi kubva pakushanda.
2. If any abnormal situation occurs with the handwheel, please stop using it immediately and troubleshoot. Before troubleshooting, it is forbidden to use the faulty handwheel again to avoid safety accidents caused by unknown handwheel faults;
3. Kana kugadziriswa kunodiwa, Ndokumbira ubate Mugadziri. Kana kukuvara kwacho kuchikonzerwa nekuzvigadzirira, Mugadziri haazope waranti