Description

1. Fampidirana vokatra
The crawler vehicle rope saw automatic cutting remote control is suitable for crawler rope saw cutting machines. It adopts 485ModbusRTU protocol to control the speed start and front and rear left and right direction control of the left and right crawler inverters, as well as the large motor frequency conversion RTU protocol to control the speed start and front and rear left and right direction control of the left and right crawler inverters, and the large motor frequency conversion over-current analysis and comparison, automatically adjust the left and right crawler speeds in real time to achieve automatic cutting function.
2. Endri-javatra vokatra
1. Manatera ny teknolojia fifandraisana Wireless 433Mhz, Ny elanelam-pifandraisana Wireless dia 100 metatra.
2. Adopt otomatic fatra-miasa, Ampiasao 32 sets of wireless remote controllers at the same time, tsy misy fiatraikany.
3. Support all inverters with 485-Modbus RTU protocol. The inverter brands that have been adapted include:Shanghai Xielin, Fuji, Inovance, Zhongchen, Invt, Anchuanda. If the brand is not ada please contact us for customization.
4. Support large motor inverter start, speed regulation, and current reading.
5. Support left and right crawler inverter speed regulation, start, front and back left and right control.
6. Support left and right crawler inverter straight line correction to keep the machine moving in a straight line.
7. Support rope saw automatic cutting function, automatically adjust the left and right crawler speed in real time according to the large motor current information.
8. Mandritra izany fotoana izany, it is compatible with direct IO output to control the start and stop of the motor, and analog voltage output to control the motor speed.
3. Famaritana momba ny vokatra

4. Fampidirana ny vokatra fampidirana

-tsoratra:
Fampisehoana ①screen:

②mode switch:
Using a 2-level switch, it is possible to switch between automatic and manual modes, and the corresponding mode will be displayed on the screen for switching.
③ Enable:
Bokotra mitambatra, Ny fandidiana sasany dia mitaky ny hanakana ny bokotra ahafahana miasa, please refer to the instructions for each switch for details.
④ Large motor switch:
Mampiasa switch 3-hafainganam-pandeha, Ny fisintonana ity kofehy ity dia afaka mifehy ny fandrosoana sy ny fihodinan'ny motera lehibe. Aorian'ny famoahana azy, Hitoetra ny fanjakana, Ary hisy fampisehoana mifanandrify eo amin'ny efijery. The t arrow indicates forward rotation, and the y arrow indicates reverse rotation.
⑤small môtô form for forward / mifamadika:
Using a 3-speed self-locking switch, pulling this switch can control the small motor to move forward and backward. The corresponding display will show on the screen, with the t arrow indicating forward and the ↓ arrow indicating backward.
⑥Remote control power switch:
Mihodina ny efijery fampisehoana lavitra.
⑦ small motor turning switch:
Mampiasa switch 3-hafainganam-pandeha, Rehefa miasa ara-dalàna, Ny môtô kely dia azo fehezina mba hivadika miankavia na havanana. Indray mandeha namoaka, the remote control will automatically stop this action.When in the forward state, turn this switch and the corresponding display will appear on the screen.The + arrow indicates left turn, ary ny – arrow indicates right turn.When in reverse mode, turn this switch and the corresponding display will appear on the screen.The + arrow indicates left turn, ary ny – arrow indicates right turn.Press and hold the enable button, then turn this switch to perform a stationary turning function, making the turn faster.
⑧ Fitsipiky ny hafainganam-pandeha lehibe:
Mampiasa knb multi multi, rotate the knob to adjust the speed S1 of the large motor For every 1 grid rotation, Ny sandan'ny hafainganam-pandehan'ny fiara fitaterana lehibe 0.2 vondrona, and rapid rotation can quickly modify the speed value of the large motor.
9 Small motor speed regulation (linear correction):To use the multi turn encoder knob, Amin'ny fomba manual, for every 1 turn of the knob, the speed value of the small motor changes by approximately 0.1 vondrona. Fast rotation can quickly modify the speed value of the small motor.
In automatic mode, press the enable button and rotate 1 grid isaky ny mandeha. The speed limit value F of the small motor changes by approximately 0.1 vondrona. Rapid rotation can quickly modify the speed limit value of the small motor.Press the enable button, turn the knob to the right, and the straight line correction display shows D f: ANKA. Each rotation of the knob increases by 1 unit; Mihodina miankavia, fampisehoana tsipika mahitsy tsipika: DF: TSARA. Each rotation of the knob increases by 1 unit, and each correction unit corresponds to a motor speed control AVI voltage of about 0.02 V.
5. Kianjanika vokatra

6. Guide fametrahana vokatra
6.1 Dingana fametrahana vokatra
1. Install the receiver in the electrical cabinet through the buckle on the back, or install it in the electrical cabinet through the screw holes at the four corners of the receiver.
2. Jereo ny sary an-tsokosoko mpandray anjara, compare your on-site equipment, and connect the equipment to the receiver through wires.
3. After the receiver is fixed, the antenna equipped with the receiver must be connected, and the outer end of the antenna must be installed or placed outside the electrical cabinet. Dia natokana hametraka izany eo an-tampon'ny kabinetra elektrika ho an'ny vokatra tsara indrindra. It is forbidden to leave the antenna unconnected or place the antenna inside the electrical cabinet, which may cause poor signal and unusable.
4. Farany, install the battery in the remote control, Hamafiso ny fonon'ny bateria, and then turn on the power switch of the remote control. After the remote control display shows the normal working interface, you can perform remote control operation.
6.2 Famaranana fametrahana refesina

6.3 Kisary referengar

7. Torolàlana momba ny asa
7.1 Fanaraha-maso ny fanaraha-maso lavitra
How to enter the background parameters of the remote controller: turn the mode switch to manual mode, amboary ny hafainganam-pandehan'ny motera kely mankany 25, na 0, 10, 20, 40, 50, and turn the forward switch of the large motor upwards 3 times and downwards 3 fotoana;
Ampiasao ny “Ny fifehezana ny hafainganam-pandeha maoderina” knob to turn the page, press Enable and turn the small motor speed control knob to modify the parameters; after modification, Avereno mankany amin'ny farany ny pejy, select Save and Exit, and press the Enable button to exit the menu;
Toy izao manaraka izao ny tarehimarika:Ny tena ambony indrindra: large motor current feedback value range, setting range 15-200A, toerana misy anao 60;
Fehezan-dalàna fifehezana hafainganam-pandeha: automatic mode small motor automatic acceleration speed, ny kely kokoa ny haingana kokoa, setting range 200-1500, toerana misy anao 1000;
Fehezan-dalàna fametahana: Set the upper limit of the motor speed change allowed. Rehefa miova izao ny vidiny ankehitriny, it will decelerate. The smaller it is, the faster the left and right motors will decelerate. The range is 05-12, and the default is 06;
Acceleration A1: The larger the value, the faster the motor speed increases, range 00-06,default 01; Seceleration A2: The larger the value, the faster the motor speed decreases, isan-karazany 00-06, toerana misy anao 02;
Mamela ny fifehezana hafainganam-pandeha: Whether the small motor speed regulation needs to be enabled, 00 is not enabled, 01 is enabled, toerana misy anao 01;
Startup self-locking: Whether the large motor will automatically keep self-locking after the forward and reverse switch is released, 00 is not maintained, 01 is maintained, toerana misy anao 01;
Maximum travel: Maximum speed of the left and right motors, isan-karazany 10-100, toerana misy anao 50;
Manapaka ny ankehitriny: Maximum cutting current, the screen displays IC value, isan-karazany 15-160, toerana misy anao 30, the screen displays IC: 30. The upper limit of this parameter = maximum current x 80%;
Default speed limit: The default small motor automatic cutting speed at startup, isan-karazany 00-100, toerana misy anao 10, the screen displays F1.0, this parameter is only accurate when the maximum travel is set to 50.
Wireless channel: Default is 10. When the remote control signal is unstable or there is signal interference on site, you can modify this parameter to switch channels to avoid interference;
Fomba fanodinana hafainganam-pandeha: The upper limit of the automatic cutting speed of the small motor,isan-karazany 00-200, toerana misy anao 60, the screen displays 6.0; Display value upper limit = speed limit offset × 0.1;
Host-Hostur: The maximum speed of the large motor, isan-karazany 10-100, toerana misy anao 50;
Mbus device ( mandatory ): large motor inverter model selection, isan-karazany 00-03, toerana misy anao 03;
00- Shanghai Xielin 01 Fuji
02- Invt 03 Inovance(Zhongchen, Robicon)
Fitaovana sbus (mandatory): Safidy kely môtô converer converter modely, isan-karazany 00-05, toerana misy anao 03;
00- Shanghai Xielin 01 Fuji
02- Invt 03 Inovance(Zhongchen, Robicon)
04-Anchuanda 05-Tsia
8. Product troubleshooting

7.2 Fametahana parameter amin'ny converterrequency
1. Safidy loharano: Channation Command Community
2. Ny fisafidianana loharanom-baovao matetika: fifandraisana omena
3. Baud rate: 19200
4. Data format: Tsy misy fanamarinana, Data format<8-N-1>
5. Adiresy eo an-toerana: Apetraho ny fiovam-po ankavia 1, ny tsy fivadihana mety 2, and the large motor frequency converter to 3
7.3 Torolàlana fanaraha-maso lavitra
1. Hery amin'ny milina, Mihodina ny fanaraha-maso lavitra, enter the remote control background, set the remote control background parameters, mainlyIt is to set the models of small and large motor frequency converters (skip this step if the machine manufacturer has already set them);
2. Set the parameters of the frequency converter (Halaviro ity dingana ity raha efa nametraka azy ny mpanamboatra milina);
3. Set the remote control to manual mode, and then use the remote control to move the machine to the working position;
4. In manual mode, set the IC value for the cutting current of the large motor and the speed of the large motor;
5. Switch to automatic mode and set the cutting speed limit F value for the small motor;
6. In automatic mode, turn the large motor switch to forward to start the large motor, and then turn the small motor switch to forward or reverse. The remote control enters automatic cutting mode and begins cutting.
9.Maintenance
1. Please use it in a dry environment at room temperature and pressure to extend its service life.
2. Please avoid using in abnormal environments such as rain and water bubbles to extend the service life.
3. Please keep the battery compartment and metal shrapnel area clean.
4. Please avoid damaging the remote control due to squeezing and falling.
5. Raha tsy ampiasaina mandritra ny fotoana maharitra, please remove the battery and store the remote control and battery in a clean and safe place.
6.During storage and transportation, attention should be paid to moisture and shock resistance.
10. Fampahalalana momba ny fiarovana
1. Please read the instructions carefully before use and prohibit non professionals from operating.
2. Please replace the battery in a timely manner when the battery is too low to avoid errors caused by insufficient power, which may result in the remote control being unable to operate.
3. Raha ilaina ny fanamboarana, Azafady mba mifandraisa amin'ny mpanamboatra. If the damage is caused by self repair, Ny mpanamboatra dia tsy hanome warranty